Services

Cleanroom Filter Selection Guide: 3 Steps to Choose High-Efficiency Air Filters

I. Understanding 3 Critical Filter Types for Cleanrooms

1. Primary Filters – First Defense Against Macroparticles

  • Function: Capture visible contaminants (dust >10μm, hair, fibers)
  • Key Features:
    • Washable synthetic fiber media (typically G4/F5 grade)
    • Initial pressure drop <50 Pa at 2m/s face velocity

2. Medium-Efficiency Filters – Intermediate Protection

  • Performance:
    • Arrestance: 90-95% for 1-10μm particles (F7-F9 EN779 standard)
    • Typical applications: Pre-filters for HEPA systems

3. HEPA Filters – Ultimate Microbial Control

  • Technical Specifications:
    • Minimum 99.97% efficiency @ 0.3μm MPPS (Most Penetrating Particle Size)
    • Certified under EN1822-1 (H13-H14) or IEST RP-CC001.6 standards

II. 3 Performance Parameters for Optimal Selection

1. Filtration Efficiency

  • Testing Standards:
    • ASHRAE 52.2 (MERV ratings) for general filters
    • ISO 29463 for HEPA/ULPA filters

2. Pressure Drop & Energy Consumption

  • Operational Economics:
    • Every 25Pa reduction in pressure drop = 15% energy savings
    • Recommended initial resistance: ≤220 Pa (HEPA)

3. Dust Holding Capacity

  • Industry Benchmarks:
    • Primary filters: ≥400g/m² (ASHRAE synthetic dust)
    • HEPA filters: ≥500g/m² (per EN1822-5)


III. 4-Step Implementation Strategy

1. Cleanroom Classification Compliance

ISO Class Recommended Filtration System Application Examples
ISO 5 (Class 100) Primary + F8 + H13 + FFU Array Semiconductor Fabs
ISO 7 (Class 10,000) Primary + F9 + H13 Pharmaceutical Sterile Areas
ISO 8 (Class 100,000) Primary + F7 Medical Device Packaging

2. Material Compatibility Matrix

Environment Challenge Recommended Construction
High Humidity (>80% RH) Stainless steel frame with hydrophobic media
Chemical Exposure PTFE membrane filters with PP housing
Fire Safety UL900 Class 1 certified filters

3. Installation Best Practices

  • Airflow Configuration:
    • Unidirectional vertical flow: 0.45m/s ±20% for ISO 5
    • Filter-sealant compatibility: Silicone-free polyurethane for pharma

4. Maintenance Protocol

Filter Type Replacement Indicators
Primary ΔP ≥ 2× initial value
HEPA 1. ΔP ≥ design limit
2. Integrity test failure (DOP/PAO test >0.01%)

IV. Expert Recommendations

  1. Cost Optimization: Implement differential pressure monitoring with IoT sensors
  2. Regulatory Compliance:
    • FDA CFR 210/211 for pharma
    • NEBB certification for critical environments
  3. Sustainability: Consider 90% recyclable Mini-Pleat HEPA filters

Technical Validation

  • Standards Compliance: Aligns with ISO 14644-4 (Design/Implementation) and IEST guidelines